STRWTR          START WRITER                           TAAPRTN

The Start  Writer command  is intended  to be  used to  start either  a
local  or remote  output queue.   Based  on the  named output  queue, a
command prompt appears for either STRPRTWTR or STRRMTWTR.

A typical command would be:

             STRWTR     OUTQ(xxx)

A  prompt would appear  for either STRPRTWTR  or STRRMTWTR depending on
the type of output queue.

STRWTR escape messages you can monitor for
------------------------------------------

      TAA9891    STRRMTWTR failed

Escape messages from based on functions will be re-sent.

STRWTR Command parameters                             *CMD
-------------------------

   OUTQ          The qualified  name of  the  output queue  to start  a
                 writer to.   The library  value defaults to *LIBL.   A
                 specific library or *CURLIB may also be used.


Restrictions
------------

None.

Prerequisites
-------------

The following TAA Tools must be on your system:

     CHKOBJ3         Check object 3
     RSNLSTMSG       Resend last message
     RTVDEVPRT       Retrieve device printer
     RTVOUTQA        Retrieve output queue attributes
     SNDDIAGMSG      Send diagnostic message
     SNDESCINF       Send escape information
     SNDESCMSG       Send escape message

Implementation
--------------

None, the tool is ready to use.

Objects used by the tool
------------------------

   Object        Type    Attribute      Src member    Src file
   ------        ----    ---------      ----------    ----------

   STRWTR        *CMD                   TAAPRTN       QATTCMD
   TAAPRTNC      *PGM       CLP         TAAPRTNC      QATTCL
					

Added to TAA Productivity tools January 15, 2012