STRWTR START WRITER TAAPRTN |
The Start Writer command is intended to be used to start either a
local or remote output queue. Based on the named output queue, a
command prompt appears for either STRPRTWTR or STRRMTWTR.
A typical command would be:
STRWTR OUTQ(xxx)
A prompt would appear for either STRPRTWTR or STRRMTWTR depending on
the type of output queue.
STRWTR escape messages you can monitor for
------------------------------------------
TAA9891 STRRMTWTR failed
Escape messages from based on functions will be re-sent.
STRWTR Command parameters *CMD
-------------------------
OUTQ The qualified name of the output queue to start a
writer to. The library value defaults to *LIBL. A
specific library or *CURLIB may also be used.
Restrictions
------------
None.
Prerequisites
-------------
The following TAA Tools must be on your system:
CHKOBJ3 Check object 3
RSNLSTMSG Resend last message
RTVDEVPRT Retrieve device printer
RTVOUTQA Retrieve output queue attributes
SNDDIAGMSG Send diagnostic message
SNDESCINF Send escape information
SNDESCMSG Send escape message
Implementation
--------------
None, the tool is ready to use.
Objects used by the tool
------------------------
Object Type Attribute Src member Src file
------ ---- --------- ---------- ----------
STRWTR *CMD TAAPRTN QATTCMD
TAAPRTNC *PGM CLP TAAPRTNC QATTCL
|
Added to TAA Productivity tools January 15, 2012