WRKNETA WORK NETWORK ATTRIBUTES TAANETE |
The Work Network Attributes command provides a subfile of all network
attributes and their current values. A Change option exists to allow
a prompt for CHGNETA and the specifically selected network attribute.
The existing current value is shown during the prompt. WRKNETA
provides a significantly better interface than the system CHGNETA
command which prompts for all parameters and shows *SAME.
The command has no parameters and would be entered as:
WRKNETA
If you are not authorized to CHGNETA, the Change option is not valid.
WRKNETA escape messages you can monitor for
--------------------------------------------
None. Escape messages from based on functions will be re-sent.
Command parameters *CMD
------------------
OUTPUT How to output the results. * is the default to
display the network attributes and allow changes.
If the command is entered in batch or *PRINT is
specified, the spooled file is output using DSPNETA
OUTPUT(*PRINT).
Restrictions
------------
You must be authorized to CHGNETA to enable the Change option.
Prerequisites
-------------
The following TAA Tools must be on your system:
DSPERRMSG Display error message
EDTNETA Edit network attribute
EDTVAR Edit variable
SNDESCMSG Send escape message
Implementation
--------------
None, the tool is ready to use.
Objects used by the tool
------------------------
Object Type Attribute Src member Src file
------ ---- --------- ---------- ----------
WRKNETA *CMD TAANETE QATTCMD
TAANETEC *PGM CLP TAANETEC QATTCL
TAANETEC2 *PGM CLP TAANETEC2 QATTCL
TAANETER *PGM RPG TAANETER QATTRPG
TAANETED *FILE DSPF TAANETED QATTDDS
|
Added to TAA Productivity tools December 1, 2004